1.
J Sport Rehabil ; 28(6): 656-659, 2019 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-29952697

RESUMO

Clinical Scenario: ReBound is a portable shortwave diathermy unit used to heat tissues using the same principle as induction drum shortwave diathermy. It is unclear if ReBound can vigorously (4°C) heat intramuscular tissue as efficiently as other thermal agents. Clinical Question: In adults (P), is ReBound diathermy (I) compared with other thermal agents (C) effective at increasing intramuscular tissue temperature by 4°C (O)? Summary of Key Findings: (1) Three studies were included for review, all randomized crossover studies. (2) All studies agreed ReBound does not achieve vigorous (4°C) heating effects during a 30-minute treatment to the triceps surae muscle (depth = 1 and 3 cm). (3) Studies agreed that the heat generated by ReBound dissipates slower than (P < .001) or similar to pulsed shortwave diathermy at 3 cm and faster than moist hot packs (P < .001) at 1 cm. (4) One study found that intramuscular tissue temperatures increased more with ReBound (3.69°C [1.50°C]) than moist hot packs (2.82°C [0.90°C]) at superficial depths (1 cm, d = 0.70). (5) Two studies compared ReBound with MegaPulse II pulsed shortwave diathermy at a 3 cm depth. One found that the MegaPulse II increased intramuscular tissue temperature by 4.32°C (1.79°C) compared with the ReBound's 2.31°C (0.87°C) increase (d = 1.43). The final study reported that the MegaPulse II increased triceps surae muscle temperature by 3.47°C (0.92°C) versus ReBound at 3.08°C (1.19°C) (d = 0.37). (6) The combined results are an increase of 3.81 (1.38°C) for the MegaPulse II and 2.77 (1.12°C) for ReBound (d = 0.83). Clinical Bottom Line: Results strongly indicate that the ReBound should not be used for vigorous (4°C) heating effects in the triceps surae muscle at 1 and 3 cm. Clinicians can use ReBound when traveling or instead of moist hot packs for moderate (2°C-3°C) heating effects at deep and superficial levels (1 and 3 cm) for large treatment areas with subcutaneous fat thickness <15 mm. Strength of Recommendation: Consistent level B findings indicate that ReBound does not achieve vigorous heating effects (4°C).


Assuntos
Diatermia/instrumentação , Músculo Esquelético , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...